Sling (implant): Difference between revisions
CSV import |
CSV import |
||
| Line 1: | Line 1: | ||
Sling (implant) | |||
[[ | A '''[[sling implant]]''' is a medical device used primarily in the treatment of urinary incontinence and pelvic organ prolapse. These conditions are often caused by weakened or damaged pelvic floor muscles, which can occur due to childbirth, surgery, or aging. Sling implants provide support to the urethra or bladder neck, helping to restore normal function and alleviate symptoms. | ||
==Types of Sling Implants== | |||
Sling implants can be categorized based on the material used and the surgical technique employed: | |||
===1. Autologous Sling=== | |||
An autologous sling uses tissue harvested from the patient's own body, typically from the rectus fascia or fascia lata. This type of sling is often preferred for patients who may have a higher risk of infection or rejection of synthetic materials. | |||
===2. Synthetic Sling=== | |||
Synthetic slings are made from materials such as polypropylene mesh. These are the most commonly used slings due to their durability and ease of placement. However, they have been associated with complications such as erosion and infection. | |||
=== | ===3. Biological Sling=== | ||
Biological slings are made from processed human or animal tissue. They are designed to integrate with the patient's own tissue, reducing the risk of rejection. However, they may not be as durable as synthetic options. | |||
==Surgical Techniques== | |||
The placement of a sling implant can be performed using various surgical techniques: | |||
===1. Retropubic Approach=== | |||
In this technique, the sling is placed through an incision in the abdomen, passing behind the pubic bone. This approach provides strong support but may have a higher risk of bladder injury. | |||
===2. Transobturator Approach=== | |||
The transobturator approach involves placing the sling through the obturator foramen, which is located in the pelvic bone. This method is associated with a lower risk of bladder injury compared to the retropubic approach. | |||
===3. Single-Incision Mini-Sling=== | |||
This is a less invasive technique where the sling is placed through a single vaginal incision. It is designed to reduce recovery time and minimize complications. | |||
== | ==Indications== | ||
Sling implants are primarily indicated for: | |||
* [[Stress urinary incontinence]]: A condition where physical activity or exertion causes involuntary leakage of urine. | |||
* [[Pelvic organ prolapse]]: A condition where pelvic organs, such as the bladder or uterus, descend into or outside of the vaginal canal. | |||
==Complications== | |||
While sling implants are generally safe and effective, they can be associated with complications, including: | |||
* Mesh erosion into the vagina or other organs | |||
* Infection | |||
* Pain | |||
* Urinary retention or obstruction | |||
* Dyspareunia (painful intercourse) | |||
==Also see== | |||
* [[Urinary incontinence]] | |||
* [[Pelvic floor dysfunction]] | |||
* [[Pelvic organ prolapse]] | |||
* [[Urogynecology]] | |||
{{Medical devices}} | |||
{{Surgery}} | |||
[[Category:Medical devices]] | |||
[[Category:Urology]] | |||
[[Category:Gynecology]] | |||
Latest revision as of 23:33, 11 December 2024
Sling (implant)
A sling implant is a medical device used primarily in the treatment of urinary incontinence and pelvic organ prolapse. These conditions are often caused by weakened or damaged pelvic floor muscles, which can occur due to childbirth, surgery, or aging. Sling implants provide support to the urethra or bladder neck, helping to restore normal function and alleviate symptoms.
Types of Sling Implants[edit]
Sling implants can be categorized based on the material used and the surgical technique employed:
1. Autologous Sling[edit]
An autologous sling uses tissue harvested from the patient's own body, typically from the rectus fascia or fascia lata. This type of sling is often preferred for patients who may have a higher risk of infection or rejection of synthetic materials.
2. Synthetic Sling[edit]
Synthetic slings are made from materials such as polypropylene mesh. These are the most commonly used slings due to their durability and ease of placement. However, they have been associated with complications such as erosion and infection.
3. Biological Sling[edit]
Biological slings are made from processed human or animal tissue. They are designed to integrate with the patient's own tissue, reducing the risk of rejection. However, they may not be as durable as synthetic options.
Surgical Techniques[edit]
The placement of a sling implant can be performed using various surgical techniques:
1. Retropubic Approach[edit]
In this technique, the sling is placed through an incision in the abdomen, passing behind the pubic bone. This approach provides strong support but may have a higher risk of bladder injury.
2. Transobturator Approach[edit]
The transobturator approach involves placing the sling through the obturator foramen, which is located in the pelvic bone. This method is associated with a lower risk of bladder injury compared to the retropubic approach.
3. Single-Incision Mini-Sling[edit]
This is a less invasive technique where the sling is placed through a single vaginal incision. It is designed to reduce recovery time and minimize complications.
Indications[edit]
Sling implants are primarily indicated for:
- Stress urinary incontinence: A condition where physical activity or exertion causes involuntary leakage of urine.
- Pelvic organ prolapse: A condition where pelvic organs, such as the bladder or uterus, descend into or outside of the vaginal canal.
Complications[edit]
While sling implants are generally safe and effective, they can be associated with complications, including:
- Mesh erosion into the vagina or other organs
- Infection
- Pain
- Urinary retention or obstruction
- Dyspareunia (painful intercourse)
Also see[edit]
| Medical devices | ||||||||
|---|---|---|---|---|---|---|---|---|
This medical device related article is a stub.
|
| Surgery | ||||
|---|---|---|---|---|
|