Fractional flow reserve: Difference between revisions

From WikiMD's Wellness Encyclopedia

CSV import
No edit summary
Line 1: Line 1:
= Fractional Flow Reserve =
[[File:Image-ffr3.jpg|thumb|right|Diagram illustrating the concept of fractional flow reserve.]]
'''Fractional Flow Reserve''' ('''FFR''') is a technique used in [[cardiology]] to measure the pressure differences across a [[coronary artery]] stenosis to assess the likelihood that the stenosis impedes oxygen delivery to the heart muscle. It is a valuable tool in the diagnosis and management of [[coronary artery disease]].
'''Fractional Flow Reserve''' ('''FFR''') is a technique used in [[cardiology]] to measure the pressure differences across a [[coronary artery]] stenosis to assess the likelihood that the stenosis impedes oxygen delivery to the heart muscle. It is a valuable tool in the diagnosis and management of [[coronary artery disease]].


Line 12: Line 8:


The FFR procedure involves the insertion of a pressure wire into the coronary artery during [[angiography]]. The wire measures the pressure before and after a stenosis. The patient is often administered a [[vasodilator]] such as [[adenosine]] to induce maximal blood flow, allowing for accurate measurement of the pressure gradient across the stenosis.
The FFR procedure involves the insertion of a pressure wire into the coronary artery during [[angiography]]. The wire measures the pressure before and after a stenosis. The patient is often administered a [[vasodilator]] such as [[adenosine]] to induce maximal blood flow, allowing for accurate measurement of the pressure gradient across the stenosis.
[[File:Image-Image-ffr4.jpg|thumb|left|Pressure wire used in FFR measurement.]]


== Clinical Significance ==
== Clinical Significance ==
Line 26: Line 20:


While FFR is a powerful tool, it is not without limitations. It requires the use of adenosine, which can have side effects, and the procedure itself is invasive. Additionally, FFR measurements can be affected by technical factors such as wire drift and pressure damping.
While FFR is a powerful tool, it is not without limitations. It requires the use of adenosine, which can have side effects, and the procedure itself is invasive. Additionally, FFR measurements can be affected by technical factors such as wire drift and pressure damping.
[[File:Ffr5.jpg|thumb|right|Graph showing FFR values and corresponding clinical decisions.]]


== Related pages ==
== Related pages ==

Revision as of 18:47, 21 February 2025

Fractional Flow Reserve (FFR) is a technique used in cardiology to measure the pressure differences across a coronary artery stenosis to assess the likelihood that the stenosis impedes oxygen delivery to the heart muscle. It is a valuable tool in the diagnosis and management of coronary artery disease.

Definition

Fractional Flow Reserve is defined as the ratio of the maximum achievable blood flow in a diseased coronary artery to the maximum achievable blood flow in a normal coronary artery. It is calculated during coronary catheterization using a specialized pressure wire.

Procedure

The FFR procedure involves the insertion of a pressure wire into the coronary artery during angiography. The wire measures the pressure before and after a stenosis. The patient is often administered a vasodilator such as adenosine to induce maximal blood flow, allowing for accurate measurement of the pressure gradient across the stenosis.

Clinical Significance

FFR is used to determine the functional significance of coronary artery stenoses. An FFR value of 0.80 or less is generally considered indicative of a hemodynamically significant stenosis, which may benefit from percutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG).

Advantages

FFR provides a more accurate assessment of the need for revascularization compared to angiography alone. It helps in avoiding unnecessary procedures and in optimizing patient outcomes by targeting interventions to lesions that are truly flow-limiting.

Limitations

While FFR is a powerful tool, it is not without limitations. It requires the use of adenosine, which can have side effects, and the procedure itself is invasive. Additionally, FFR measurements can be affected by technical factors such as wire drift and pressure damping.

Related pages

See also