Gastric tonometry is a diagnostic procedure used to measure the gastric mucosal carbon dioxide (CO2) levels, which can be an indicator of the adequacy of blood flow (perfusion) to the stomach's lining. This technique is particularly useful in critical care settings to monitor patients at risk of gastrointestinal ischemia, a condition where the blood flow to the stomach is reduced or blocked, leading to tissue damage.

Overview[edit]

Gastric tonometry involves the use of a specialized catheter that is inserted through the nose or mouth and positioned in the stomach. The catheter is equipped with a balloon at its tip, which is inflated with a known amount of gas (usually CO2). Over time, the gas within the balloon equilibrates with the CO2 present in the stomach lining. By measuring the changes in CO2 levels within the balloon, healthcare providers can infer the pH level and blood flow to the gastric mucosa.

Indications[edit]

Gastric tonometry is indicated for patients who are at a high risk of developing gastrointestinal ischemia. This includes individuals with:

  • Severe trauma
  • Sepsis
  • Major surgery
  • Shock (cardiogenic, hypovolemic, or septic)
  • Conditions leading to compromised blood flow to the gastrointestinal tract

Procedure[edit]

The procedure for gastric tonometry involves several steps:

  1. Preparation of the patient, including fasting and, in some cases, sedation.
  2. Insertion of the tonometry catheter through the patient's nose or mouth, advancing it into the stomach.
  3. Inflation of the catheter's balloon with a known quantity of CO2.
  4. Allowing time for the CO2 within the balloon to equilibrate with the CO2 in the stomach lining.
  5. Measurement of the CO2 levels within the balloon, which reflects the gastric mucosal CO2 levels.
  6. Calculation of the gastric mucosal pH (pHi) based on the CO2 measurements, which provides an indication of the blood flow to the stomach lining.

Risks and Complications[edit]

While gastric tonometry is generally safe, there are potential risks and complications associated with the procedure, including:

  • Nasopharyngeal discomfort or injury
  • Gastrointestinal perforation
  • Misplacement of the catheter
  • Infection

Clinical Significance[edit]

Gastric tonometry is a valuable tool in the assessment of splanchnic perfusion, particularly in critically ill patients. By monitoring gastric mucosal CO2 levels, healthcare providers can detect early signs of gastrointestinal ischemia, allowing for timely intervention to restore adequate blood flow and prevent further complications.

Limitations[edit]

Despite its utility, gastric tonometry has limitations, including:

  • Variability in measurements due to technical factors or patient conditions
  • Need for specialized equipment and trained personnel
  • Invasiveness of the procedure, which may not be suitable for all patients

Future Directions[edit]

Research is ongoing to refine gastric tonometry techniques and expand its applications. Non-invasive methods and improved monitoring systems are being developed to enhance the safety, accuracy, and ease of use of this diagnostic tool.


Stub icon